Medical Devices Regulations 2002 (SI 2002/618), as amended
Medical Devices Regulations: servicing and manufacturer instructions
In Great Britain, medical devices are regulated under the Medical Devices Regulations 2002, enforced by the MHRA. A device placed on the market must carry a UKCA or CE mark (subject to the transitional arrangements in force) and must come with instructions for use. Many items in a dental surgery are medical devices: the treatment centre and chair, handpieces, and equipment such as suction units and compressors supplied as part of a dental system.
In plain English
In Great Britain, medical devices are regulated under the Medical Devices Regulations 2002, enforced by the MHRA. A device placed on the market must carry a UKCA or CE mark (subject to the transitional arrangements in force) and must come with instructions for use. Many items in a dental surgery are medical devices: the treatment centre and chair, handpieces, and equipment such as suction units and compressors supplied as part of a dental system.
The regulations place most of their obligations on manufacturers. For the practice, the practical duties flow from elsewhere: the CQC's fundamental standards, PUWER and the manufacturer's instructions themselves. The manufacturer's instructions are the reference for how a device should be installed, used, maintained and repaired, and following them is how a practice shows that the device is being used as intended.
The MHRA also runs the Yellow Card scheme for reporting adverse incidents involving medical devices, and publishes guidance on managing medical devices for health and social care organisations.
Who does what
Your responsibility as the provider
- Using devices for their intended purpose and in line with the manufacturer's instructions
- Keeping the instructions for use and maintenance available for each device
- Having devices maintained and repaired by people with the appropriate competence, using suitable parts
- Reporting adverse incidents involving devices to the MHRA through the Yellow Card scheme, and to the CQC where the notification rules require it
- Keeping records that identify each device (manufacturer, model, serial number) and its maintenance history
- Responding to manufacturer field safety notices and MHRA alerts that apply to devices the practice holds
What Dynamo Dental delivers directly
Some manufacturers restrict particular work to their own trained agents. Where that applies to a device we are asked to work on, we say so and can help arrange it. Otherwise, for the devices we maintain:
- Servicing and repairing chairs and treatment units, compressors, suction systems and amalgam separators in line with the manufacturer's maintenance instructions
- Installing and commissioning equipment as the manufacturer's installation instructions describe, and recording it
- Using parts that are suitable for the device, and stating on the report which parts were fitted
- Recording manufacturer, model and serial number for each device we work on, so the practice's asset register can be matched against safety notices
- Providing the engineering facts the practice needs if it decides to report an incident
Verified specialist competence, or a specialist partner
- Work a manufacturer reserves for its own service organisation: the manufacturer or its appointed agent
- Devices outside our categories (radiography, decontamination, lasers, electrosurgery): the relevant specialist
- Deciding whether an incident is reportable: the practice, using MHRA guidance
- Any modification to a device: normally only with the manufacturer's agreement, because modification can affect its status as a medical device
Outside our scope
- Claiming approval or authorisation by a manufacturer that has not been confirmed in writing
- Certifying that a device conforms to the regulations
- Regulatory advice on placing devices on the market
- Modifying devices outside the manufacturer's instructions
Questions
Questions on this topic
Do we have to use the manufacturer for servicing?
The regulations do not say who may service a device; they require it to be maintained as the manufacturer instructs. Some manufacturers reserve specific tasks or software for their own agents, and warranty terms may add conditions. Check the instructions and any warranty for your model. Where a manufacturer restriction applies to work we are asked to do, we tell you.
What should we do if a chair injures a patient or a member of staff?
Make the equipment safe and take it out of use, record what happened, and report it. Adverse incidents involving medical devices are reported to the MHRA through the Yellow Card scheme, and some incidents must also be notified to the CQC. We can provide a technical report on the equipment to support your investigation; the decision to report, and the report itself, are the practice's.
Other topics
- Health and Social Care Act 2008 (Regulated Activities) Regulations 2014, Regulation 15 (Premises and equipment)CQC Regulation 15: premises and equipment
- Health and Social Care Act 2008; Health and Social Care Act 2008 (Regulated Activities) Regulations 2014Health and Social Care Act 2008: regulated activity and equipment
- Provision and Use of Work Equipment Regulations 1998 (SI 1998/2306)PUWER 1998: Provision and Use of Work Equipment Regulations
- Pressure Systems Safety Regulations 2000 (SI 2000/128)PSSR 2000: Pressure Systems Safety Regulations and dental compressors
- Pressure Systems Safety Regulations 2000, Regulations 8 and 9 (written scheme of examination; examination in accordance with the written scheme)Written Schemes of Examination for dental compressors
- Electricity at Work Regulations 1989 (SI 1989/635)Electricity at Work Regulations 1989 and dental equipment